To remove heat from water.
Hvac chilled water system vav.
The principal objectives of chilled water pumping system selection and design are to.
Fan coils require complex chillers and boilers to provide water loop fluid in a particular temperature range i e chilled water for cooling and hot water for heating.
Variable air volume vav is a type of heating ventilating and or air conditioning system unlike constant air volume cav systems which supply a constant airflow at a variable temperature vav systems vary the airflow at a constant temperature.
At the heart of the water chilled system a chiller removes heat from water by means of a refrigeration cycle.
Developments in chilled beam have provided another choice for new and renovated facilities using hvac terminal equipment that use chilled water and heating water.
With chilled water systems chilled water piping must be installed throughout the building and this can be far more expensive to install over the plain old dx rooftop units which supply conditioned air to a vav system that has electric reheat in them.
A vav box is integral to the ductwork connecting primary ductwork to secondary ductwork.
In many cases a variable air volume box is nothing but an assembly of a sheet metal box with a damper and controls inside a control panel.
Chilled water system basics.
The water coil in the chilled beam a two pipe system for either cold or hot water or a four pipe system for simultaneous heating and cooling is controlled by the space thermostat and satisfies the space sensible load.
With reliability improvements associated with direct digital controls and vfds vav systems became the dominant hvac system of choice in the 1990s and beyond.
Chilled water systems provide cooling to a building by using chilled water to absorb heat from the building s spaces.
However the purpose of a chiller remains the same.
A variable air volume vav box is a part of an hvac system in commercial buildings.
A chilled water system is a cooling system in which chilled water is circulated throughout the building or through cooling coils in an hvac system in order to provide space cooling.
Each zone contains a vav box which varies the flow of air for zone level cooling and or heats the air to provide heating.
Two pipe fan coils have a major disadvantage as control is substantially limited to whatever mode the system is currently set at i e cooling or heating.
There is a central chilled water plant that provides cooling to the air handling unit.
The advantages of vav systems over constant volume systems include more precise temperature control reduced compressor wear lower energy.