5 3 general it is noted that the insulating qualities of xlpe are very good and.
High voltage testing of cables pdf.
Ieee 400 2 2013 ieee guide for field testing of shielded power cable systems using very low frequency vlf less than 1 hz.
Perform a shield continuity test on each power cable.
Ieee 400 4 2015.
The fundamental difference between ac and dc high voltage testing is the avoidance of space charge effects.
For high voltage test on cables and withstand tests samples have to be carefully prepared and terminated.
High potential hi pot dc testing guidelines for medium voltage cables photo credit.
Testing of high voltage cables manual horizon power 1st edition february 2013 prepared by field practices safety health.
Rated 5 kv and above with high direct current voltage.
Ac high voltage test equipment design vlf operation reduces the power required to load cables which present a capacitive load.
The responsible safety officer should be consulted regarding the equipment and the appropriate personnel protection requirements.
Stored charge in the sheath of the cable under test.
Perform an insulation resistance test individually on each conductor with all other conductors and shields grounded.
Otherwise excessive leakage or end flashovers may occur during testing.
In the absence of manufacturer s published data use table 100 1.
However there is a risk that the cable may be understated due to a combination of lower test voltage and allowed uncertainty of the measuring circuit.
Induced stored charge in the sheath and core of cores cables adjacent to the one under test.
The normal length of the cable sample used varies from about 50 cm to 10 m.
Ac is therefore recommended in most cable testing standards.
Risks associated with testing of high voltage cables.
The typical high potential hi pot test is an example of a type 1 field test.
The terminations are usually made by shielding the end conductor with stress shields or.
The most commonly used commercially available vlf ac voltage test frequency is 0 1 hz.
Test sets typically operate at 0 1hz.
Apply voltage in accordance with manufacturer s published data.
Stored charge in the core under test.
Ieee 400 3 2006 ieee guide for partial discharge testing of shielded power cable systems in a field environment.
For example if you have a wire that connects two pins the high voltage will be simultaneously apply to both of those pins and the entire wire will be raised in voltage.
The cable either passes or fails the test.